Foss Calibrator (quick mPLS overview)
I am starting to use the new software Foss Calibrator, so I will publish some posts about how it works. I use in this case the software for some samples of meat for a viability study of the calibration, and the software improves the split of the sample set into a validation and a calibration set, giving several options like random, time based,...We can choose also if the validation set is into the range of the calibration set, so the model has all the validation samples into the range of the constituent calibration, this way we have quickly the calibration and validation set ready to develop the calibration.
For the calibration we have several options for the cross validation (leave one out, using blocks, venetian blinds,......).
We can choose for developing the calibration the options: mPLS, PLS, ANN or LOCAL.I try for this case the mPLS models.
We can select the wavelength range, so we have to look to the spectra to see how if looks and remove noisy part of the spectra, or remove the visible part,.....
The XY plot of Measured vs Predicted shows the calibration and validation samples overlapped and is quite useful for a quick idea of the performance of the model.
We have also the plot of the GH distances with the calibration and validation values overlapped:
We see the statistics of the model and this time the RMSEP is the total error and the SEP is the error with the bias correction which makes easier to compare the results with other software or literature.
We can publish the model (calibration and outlier model together) to a folder in our PC and get the ".eqa", ".pca", and ".lib" files to use in Win ISI or load in MOSAIC Network or Solo, and get a report of the calibration.
I will continue sharing my experience with Foss Calibrator with the Label "Learning Foss Calibrator"
1 dic 2018
"R" en la Jornadas Técnicas NIR de FOSS
El pasado martes 27 de Noviembre se celebraron en Madrid la Jornadas Técnicas NIR de FOSS, un evento anual en el que FOSS presenta en España las nuevas tendencias de la instrumentación NIR en FOSS que van dirigidas a la digitalización con productos como el "Foss Assure", "Mosaic" y "Foss Calibrator" entre otros. Con ellos el DS2500 o DA1650 (entre otros) se están convirtiendo en productos que van a poder beneficiarse de estas herramientas digitales e ir evolucionando con ellas.
Foss Calibrator será la nueva plataforma de calibración que sucederá a Win ISI en un futuro próximo. Por supuesto Win ISI ha estado presente en las Jornadas y también ha sido para mí un placer que "R" lo estuviese en mi ponencia.
"R" despertó un gran interés de lo cual me alegro, ya que los usuarios de este software deseamos promocionarlo para que se vea y use el enorme potencial que tiene.
Foss Calibrator será la nueva plataforma de calibración que sucederá a Win ISI en un futuro próximo. Por supuesto Win ISI ha estado presente en las Jornadas y también ha sido para mí un placer que "R" lo estuviese en mi ponencia.
"R" despertó un gran interés de lo cual me alegro, ya que los usuarios de este software deseamos promocionarlo para que se vea y use el enorme potencial que tiene.
Un placer escuchar a @jrcuesta hablando de NIR y Quimiometria en la Jornada Técnica NIR de FOSS. Siempre se aprende algo nuevo. pic.twitter.com/GMHUNQbdjr— SECRAN (@SECRAN3) 27 de noviembre de 2018
11 nov 2018
Variable Importance in NIR "PLS" Models (CARET)
This is a function of the R Caret package to check the importance of the variables in a regression. In the case of the model developed with the sunflower seed to determine oleic acid (model_oleic), we can plot it and check which variables have more importance and this is done with a simple step:
varImp_pls<-varImp(model_oleic)
And the best way to check it is plotting the results as a spectrum:
matplot(wavelengths,varImp_pls$importance,type="l",
xlab="wavelengths",
ylab="importance",
ylim =c(min(varImp_pls$importance)-0.1,
max(varImp_pls$importance)+0.1),
col="blue")
xlab="wavelengths",
ylab="importance",
ylim =c(min(varImp_pls$importance)-0.1,
max(varImp_pls$importance)+0.1),
col="blue")
To obtain this spectra:
We can see that the zone of 1700 to 1800 has higher important than the rest due to the peaks linked to the "oil" around 1720 and 1760 nm.
8 nov 2018
¿Cuando los resultados que predice el NIR son fiables?
Esta es una de las preguntas más comunes que se hacen los usuarios del NIR y que voy a tratar de simplificar una respuesta.
Cuando se instala un modelo de calibración, este lleva unos estadísticos que indican los errores de la calibración, y se conocen como:
SEC (Error Estándar de Calibración) y SECV (Error Estándar de Validación Cruzada)
Posteriormente a la instalación de la ecuación para su uso en rutina, y cuando ya tenemos unas 20 muestras de cada parámetro, podemos calcular el SEP (Error Estándar de Predicción) y hacer una comparativa de los tres errores para sacar conclusiones. La situación ideal es cuando los tres estadísticos de error son parecidos y lo suficientemente bajos como para poder usar la aplicación por NIR .
Tenemos que tener en cuenta que conocer el error de laboratorio (SEL) nos ayudará a conocer el ratio de error entre el NIR y el Laboratorio y tomar también decisiones para ver como bajarlo (presentando la muestra de modo diferente,....,etc).
Cuando validamos y calculamos el SEP, podemos generar otros estadísticos para ver si la ecuación se está comportando correctamente o no, basándonos en la ecuación que tenemos instalada y para ello se necesitan el número de muestras que hay en la calibración instalada así como el número de términos que se usó, el nivel de confianza que queremos y el SEC o SECV. Con ello se generan unos limites de confianza para el Bias, la Pendiente y el SEP. En el caso de que los resultados estén dentro de los límites, podemos seguir usando el modelo con confianza en los márgenes de error dados inicialmente.
Este es un ejemplo:
En un modelo para Oleico en pipa de Girasol molida (con molino de tipo Moulinex), con 109 muestras, 5 términos , un nivel de confianza de 95% y un SECV de 2,21 los resultados del test de la ISO 12099:2010 son:
Como podemos comprobar el SEP está dentro de los límites previstos y el modelo puede seguir siendo usado. No obstante tenemos que sacar conclusiones para ver como mejorarlo, y el XY plot nos puede ayudar:
Parece probable que con una mejora en la molienda de la muestra, con replicados, u otros métodos de presentación el modelo puede ser mejorado, pero tal como se está realizando actualmente es operativo.